NCIR featured with built-in infrared MLX90614 sensor, It can be used to measure the surface temperature of a human body or other object.
Unlike most temperature sensors, this sensor measures infrared light bouncing off of remote objects so it can sense temperature without having to touch them physically.
Simply point the sensor towards what you want to measure and it will detect the temperature by absorbing IR waves emitted. Because it doesn't have to touch the object it's measuring, it can sense a wider range of temperatures than most digital sensors! It takes the measurement over an 90-degree field of view so it can be handy for determining the average temperature of an area.
The MLX90614 is factory calibrated in wide temperature ranges: -40 to 125 ˚C for the ambient temperature and -70 to 380 ˚C for the object temperature.
Connect with M5Core via GROVE A I2C(0x5A).
Resources | Parameter |
---|---|
Communication protocol | I2C:0x5A |
Net weight | 4g |
Gross weight | 16g |
Product Size | 32*24*8mm |
Package Size | 67*53*12mm |
EasyLoader is a concise and fast program writer, which has a built-in case program related to the product. It can be burned to the main control by simple steps to perform a series of function verification.
M5Core (GROVE A) | GPIO22 | GPIO21 | 5V | GND |
---|---|---|---|---|
NCIR Unit | SCL | SDA | 5V | GND |
Non-contact temperature measurement, direct reading data