HEART is built using the MAX30100 chipset.
MAX30100 is a complete pulse oximetry and heart-rate sensor system solution designed for the demanding requirements of wearable devices.
The MAX30100 provides very small total solution size without sacrificing optical or electrical performance. Minimal external hardware components are needed for integration into a wearable device.
Put your finger on the detection area.
I2C(0x57).
Resources | Parameter |
---|---|
Communication protocol | I2C:0x57 |
Net weight | 5g |
Gross weight | 18g |
Product Size | 32*24*8mm |
Package Size | 136* 92* 13mm |
EasyLoader is a concise and fast program writer, which has a built-in case program related to the product. It can be burned to the main control by simple steps to perform a series of function verification.
M5Core(GROVE A) | GPIO22 | GPIO21 | 5V | GND |
---|---|---|---|---|
HEART Unit | SCL | SDA | 5V | GND |
Datasheet
To get the code, please click here
QUESTION:The accuracy of the Heart rate unit, what is the resolution?
ANSWER:Since it has not been calibrated and officially verified, the data can only be used as a reference, but if the number is suddenly low, you should pay special attention to whether the body is abnormal. The actual test can hold your breath for a period of time and then measure the blood oxygen concentration will be low; The right hand finger measurement is also slightly lower, which may be related to the distance from the heart.